01
Why digital therapeutics are hard to commercialize
Building the app is the smaller task. The harder tasks are showing the intervention works, finding a reimbursement route, and getting patients to complete the program. Clinical evidence takes time and money. Payers, employers and health systems each want different proof, and coverage for software is uneven.
Engagement is a clinical variable, not a growth metric. If users stop after week two, the dose of the intervention is too low to measure an effect. That pushes design toward onboarding, personalization, clinician touchpoints and measurement from the first prototype.
- Regulatory status depends on intended use, claims and risk, and it can change as you add features or marketing language.
- Randomized evidence for software is expensive, and blinding and control design are difficult.
- Quality system obligations arrive earlier than most startups expect if you pursue a device pathway.
- Prescription or provider-recommended distribution requires integration with clinical workflows.
02
What we build for digital therapeutic products
Intervention engine and content delivery
Modular session logic, branching, personalization rules and content versioning, so clinical teams can edit approved content without a code deploy and every change is traceable.
Patient app and engagement design
Onboarding, daily tasks, reminders, progress and in-app measures such as PHQ-9 or a condition-specific scale. Accessibility is part of the clinical design, not an add-on.
Clinician and prescriber tools
Referral or prescription intake, patient status dashboards, adherence flags and summaries for the chart, built on FHIR and SMART on FHIR where useful.
Evidence and analytics pipeline
Event capture, outcome data, audit trails and exports for biostatisticians, with a data dictionary and change control. See healthcare analytics platforms for the data layer.
Adaptive and AI-assisted features
Personalization models can improve engagement but may change regulatory status and require validation and monitoring. We separate model components and document their intended use.
03
Digital therapeutic architecture and design controls
We separate the therapeutic logic from the delivery shell. The intervention engine is a versioned, tested module with explicit inputs and outputs. The patient app, clinician portal and analytics layer consume it through a defined API. That separation keeps the safety-relevant code small and makes change impact easier to assess.
A typical stack is native or React Native clients, a TypeScript or Kotlin backend, PostgreSQL, a content management layer with approval workflow, an event stream for outcomes, and infrastructure as code with release-controlled environments. If you pursue a device pathway, we add requirements traceability from user needs to tests, a software bill of materials, risk-linked test cases and a documented release process in line with IEC 62304 and ISO 14971.
The trade-off is speed versus control. Heavy documentation from day one slows a prototype. We usually run a lightweight discovery phase with prototype code kept apart from the code intended for regulated release, then move to controlled development once the intended use is stable.
04
When digital therapeutics are regulated devices
In the US, software that is intended to treat, diagnose, cure, mitigate or prevent disease can meet the definition of a device under the Federal Food, Drug, and Cosmetic Act, including when it runs on a general-purpose phone. FDA calls this Software as a Medical Device (SaMD) when the software is itself the device. Depending on risk, pathways include 510(k), De Novo classification and premarket approval. FDA also publishes policies describing some low-risk software functions for which it does not intend to enforce device requirements, and the general wellness policy covers some low-risk wellness claims.
Whether your product falls inside those policies depends on its specific claims, users and risks. Wording on the app store page, in sales decks and in clinical studies counts as evidence of intended use. We do not make that determination for you. We help you assemble the facts and recommend you work with regulatory counsel or a regulatory consultant.
Device-pathway products also expect a quality management system (FDA is transitioning 21 CFR Part 820 to align with ISO 13485), usability engineering under IEC 62366-1, and cybersecurity documentation. If your product is a cyber device, section 524B of the FD&C Act adds premarket cybersecurity expectations. Separately, HIPAA, the FTC Health Breach Notification Rule and state privacy laws govern the data.
05
Integrations a digital therapeutic needs
- EHR launch, referral and results exchange via EHR/EMR integration services and FHIR APIs.
- Prescription or authorization routing through specialty pharmacy or digital distribution partners, where your model uses it.
- Wearables and sensors for passive measures, through wearable device integration.
- Clinical trial data systems such as EDC platforms and CDISC-oriented exports for evidence generation, relevant to life sciences sponsors.
- Payer, employer and benefits platforms for eligibility, access codes and reporting.
06
How we deliver a digital therapeutic
Intended use and regulatory strategy
Workshop to draft intended use, user groups, claims and a risk view. Deliverable: a documented position and a list of open questions for your regulatory advisor.
Prototype and evidence plan
A clickable and technical prototype for patient and clinician testing, and a measurement plan agreed with your clinical and statistical leads.
Controlled development
Requirements, architecture, verification and validation, traceability and release records at the level your pathway needs.
Pilot, study support and iteration
Instrumentation for studies, remote monitoring of engagement and defect handling, with change control for post-launch updates.
07
Digital therapeutic use cases
- A CBT-based program for insomnia or anxiety with clinician oversight and outcome measures.
- A condition self-management program for diabetes, hypertension or chronic pain with structured education.
- A substance use disorder support program integrated with a treatment clinic's workflow.
- A pediatric or rehabilitation program with caregiver participation and therapist dashboards.
- A pharma-sponsored companion that supports adherence and gathers real-world data alongside a drug therapy.
08
Digital therapeutics cost and timeline factors
Regulatory pathway, evidence needs and quality system overhead matter more than feature count. These ranges are planning estimates for the engineering effort only, and do not include clinical studies or regulatory submission fees. They are not quotes.
| Scope tier | Typical timeline | Main cost drivers |
|---|---|---|
| Prototype for evidence planning | 2 to 4 months | Intervention design, usability testing, measurement plan |
| Pilot-ready product, non-device or wellness position | 5 to 9 months | Content tooling, engagement features, analytics, privacy |
| Product built for a device pathway | 12 to 24 months or more | Quality system, verification, cybersecurity, traceability, usability studies |
Frequently asked questions
Is every digital therapeutic an FDA-regulated device?
No. It depends on intended use, claims and risk. Software meant to treat or manage a disease often meets the device definition, while general wellness or administrative software may not. FDA also has enforcement policies for some low-risk functions. Confirm your position with regulatory counsel before launch.
Do you help get FDA clearance?
We build software with regulated-development practices and prepare engineering documentation such as requirements, risk-linked tests and traceability. Clearance decisions rest with FDA, and the submission and strategy are typically led by your regulatory team or consultants. We do not promise any outcome.
Which standards apply to the software?
For device software, teams commonly use IEC 62304 for the software lifecycle, ISO 14971 for risk management, IEC 62366-1 for usability and ISO 13485 for the quality system. Which are required depends on your pathway and markets. See medical device software development.
Can AI personalize therapy content?
It can, but model-driven changes to a therapeutic can alter risk and regulatory status. FDA has issued guidance on predetermined change control plans for AI-enabled device software functions. We keep models separable, validate on relevant data, monitor in production and keep clinicians informed.
How do we get paid for a digital therapeutic?
Routes include payer coverage, employer and health system contracts, pharma partnerships and direct pay. Coverage for software remains uneven and depends on evidence and regulatory status. We build the reporting and eligibility features each route needs, but the business case should be tested during discovery.
Sources and further reading
- FDA: Digital Health Center of Excellence
- FDA: Software as a Medical Device (SaMD)
- FDA: General Wellness policy guidance
- FDA: Cybersecurity in Medical Devices
This page is general information, not legal or regulatory advice. Requirements depend on your product, data and organization; consult qualified counsel for your situation.