01
Why device software projects stall or get rejected
The usual causes are process, not code. Teams ship an MVP at startup speed, then discover that the requirements, risk file and test records a regulatory submission needs were never written. Reconstructing them after the fact is slow and rarely convincing.
The opposite failure also happens. A team adopts heavyweight process for a function that is not a device, and spends months on documents the product did not require. Knowing which functions are in scope is the first engineering decision.
- Unclear intended use, which drives classification, evidence needs and the pathway
- No design history that links user needs, requirements, risks, code and verification
- Third-party libraries and operating systems (SOUP, software of unknown provenance) with no assessment
- Cybersecurity treated as an afterthought, although FDA expects it to be part of premarket design
- Changes after release that trigger re-verification or new submissions because nobody assessed their impact
02
What our medical device software engineering covers
Requirements and design controls
User needs, system requirements and software requirements captured in a traceable form, with design inputs and outputs reviewed and baselined. We align with the design control expectations in 21 CFR Part 820 and ISO 13485 as they apply to your quality system.
Embedded and firmware development
C and C++ (and Rust where it fits) on an RTOS or bare metal, BLE and Wi-Fi connectivity, secure boot and signed updates, power management, and hardware abstraction layers that make the code testable off the target.
SaMD and connected app software
Mobile, web and cloud software that performs a medical purpose, including algorithm integration, configuration management for algorithm versions, and data pipelines that preserve provenance. If your algorithm uses machine learning, we plan change control with FDA's guidance on predetermined change control plans in mind.
Software risk management
Hazard analysis, software safety classification under IEC 62304, risk controls built into the design and verified by test, aligned with ISO 14971 practice. Risk controls are traced to requirements and tests.
Verification, validation and usability
Unit, integration and system test with traceable results, static analysis, and support for summative usability evaluation under IEC 62366-1 practices with real users in representative settings.
03
Medical device software architecture and lifecycle
IEC 62304 asks you to decompose software into items and units, assign a software safety class (A, B or C) based on the severity of harm a failure could contribute to, and apply process rigor accordingly. A good architecture isolates the safety-relevant functions so the highest-rigor process applies to as little code as possible.
In practice that means a small, well-specified core that handles measurement, control or algorithm output, separated from user interface, connectivity and analytics. The core is written to be deterministic and testable on a host machine as well as on the target. Interfaces between partitions are explicit, and failures in non-critical parts cannot corrupt the critical core.
Third-party components are managed deliberately. Each operating system, library or SDK gets a SOUP record: version, intended use, known anomalies and the rationale for using it. We keep a software bill of materials, because FDA expects one in premarket cybersecurity documentation for cyber devices.
The build pipeline is part of the design. We use reproducible builds, a CI system that runs the test suite and static analysis on every change, signed release artifacts, and a requirements-management tool or structured repository from which the traceability matrix is generated rather than hand-maintained.
For connected devices, the cloud side is part of the system. Update delivery, device identity, telemetry and clinician-facing apps have their own safety and security analysis, and the interfaces to the device are specified and versioned.
04
Cybersecurity and regulatory pathway for device software
Whether your software is a medical device depends on its intended use and the claims you make. Software intended for a medical purpose can be a device regardless of whether it runs on dedicated hardware. Classification and pathway (510(k), De Novo, PMA, or exempt) depend on risk and on predicate devices. Regulatory counsel or a regulatory consultant should confirm these.
FDA expects cybersecurity to be addressed in premarket submissions for devices that meet the statutory definition of a cyber device. That has included threat modeling, a software bill of materials, a vulnerability management plan and the ability to patch. Treat the specific current requirements as something to verify against FDA's current guidance.
- Required (when applicable): design controls and a quality system under 21 CFR Part 820, and premarket or exemption obligations for your classification
- Required (when HIPAA applies): Security Rule safeguards for ePHI handled by connected components
- Recommended: threat modeling early in design, with security requirements traced like any other requirement
- Recommended: secure boot, signed and versioned firmware, and a defined end-of-support policy
- Recommended: post-market monitoring of vulnerabilities in every third-party component
05
Connecting devices to apps, the cloud and clinical systems
- BLE, Wi-Fi, USB and serial connectivity with defined, versioned protocols, as detailed in medical device integration
- Companion mobile apps for setup, configuration and data display; see medical device companion app development
- FHIR and HL7 v2 export of results to EHRs through FHIR integration services and HL7 integration services
- Device fleet management, secure over-the-air updates and telemetry, related to healthcare IoT integration
- Standards where relevant, such as IEEE 11073 for device communication and IHE profiles for point-of-care devices
- Cloud services for algorithm updates, data storage and clinician portals
06
How we run a device software project
Phase 1: Intended use and classification workshop
We pin down intended use, user, environment and claims, and identify which software functions could be in regulatory scope. Deliverable: an intended-use statement, a preliminary software safety classification and a plan for regulatory review with your advisor.
Phase 2: Planning and architecture
Software development plan, risk management plan, architecture with safety partitioning, SOUP list and verification strategy. Deliverable: baselined planning documents and architecture design.
Phase 3: Implementation and verification
Iterative development within the plan, with reviews, static analysis, unit and integration test, and a living traceability matrix. Deliverable: verified software items, test records and a design history file contribution.
Phase 4: Validation support and release
System-level verification, usability support, release documentation and a controlled release. Deliverable: release package, anomaly list and a maintenance and change-control procedure for post-release updates.
07
Where medical device software work applies
- Connected diagnostic or monitoring devices with embedded firmware, a mobile app and a cloud backend
- Standalone SaMD that analyzes images, signals or questionnaires and presents results to a clinician
- Therapy delivery devices such as infusion, neurostimulation or respiratory equipment with a control UI and data logging
- Digital therapeutics that need design controls around the intervention, see digital therapeutics development
- Remediation of an existing codebase so it can meet design control expectations before a submission
- Post-market sustaining engineering: patches, security updates and change-impact assessments
08
Medical device software cost and timeline factors
Cost follows risk class, scope of embedded work and the documentation burden, which scales with the software safety class. Hardware, clinical studies, regulatory fees and notified-body or FDA review time are separate from software engineering and are often the longest part of the calendar. These ranges are planning estimates for the software work only.
| Scope tier | Typical timeline | Main cost drivers |
|---|---|---|
| Companion or SaMD app, lower software safety class | 5 to 9 months | Intended use clarity, documentation volume, usability testing |
| Connected device: firmware, app and cloud, mid safety class | 9 to 15 months | Embedded work, hardware availability, cybersecurity, V&V |
| Higher-risk therapy or control software, class C elements | 15 to 24 months | Rigor of verification, risk controls, independent review, change control |
09
When medical device process is more than you need
If your software supports administration, scheduling, education or general wellness and makes no medical claims, a full IEC 62304 process may be unnecessary. You still need good engineering and security. Decide with qualified advice before committing, because it changes budget and timeline considerably.
Frequently asked questions
Do you provide FDA clearance?
No. FDA clearance or approval is a decision made by the agency on your submission. We build software under documented practices and produce engineering records that feed your submission. We do not guarantee any regulatory outcome, and we recommend you work with qualified regulatory counsel or a consultant.
What does IEC 62304-aware mean?
IEC 62304 is the international standard for medical device software lifecycle processes. IEC 62304-aware means we plan, document, test and control changes in line with its structure, including safety classification and SOUP management. It does not mean a certificate. Conformity to the standard is shown within your quality system.
Is our app a medical device?
It depends on intended use and claims. Software meant to diagnose, treat, mitigate or monitor a disease can be a device, while scheduling, education or general wellness features often are not. FDA's guidance on clinical decision support and general wellness helps. We recommend a documented determination reviewed by regulatory counsel.
Can you work inside our existing quality system?
Yes. If you already operate under ISO 13485 or a Part 820-aligned system, we follow your procedures and templates and produce records in your formats. If you do not have one, we can help set up a lightweight, proportionate process, with your regulatory lead owning the quality system.
How do you handle machine learning in a device?
We treat the model as a versioned, verified software item with documented training data, performance evaluation on representative data and a change-control plan. FDA has issued guidance on predetermined change control plans for AI-enabled device software functions, and we plan updates with that framework in mind, subject to regulatory review.
Sources and further reading
- FDA: Digital Health Center of Excellence
- FDA: Cybersecurity in medical devices
- eCFR: 21 CFR Part 820, Quality system regulation
This page is general information, not legal or regulatory advice. Requirements depend on your product, data and organization; consult qualified counsel for your situation.